REFERENCES

when out-of-the-box is not enough

University of Stuttgart

Retro-fit of two climate chambers at the Department of Plant Biotechnology with 6 channel LED fixtures. The project has been realized based on our SUNsim ecotune solution.

Read more about why they have chosen our LED solution.

Project specifications

  • 2 chambers with a total size of 75 m²
  • 120 LED modules (40 + 80)
  • Average max. intensity of 80 to 90 W/m² @ 400-750nm
  • Max. Power consumption 24 kW (8 + 16 kW)
  • 12 independent groups of LED fixtures (4 + 8)
  • LED-fixtures had to be integrated in separated light compartments which had to be sealed
  • All walls had to be optimized in order to meet the thought requirements regarding the homogeneity

IPK Gatersleben

Retro-fit of one climate chamber at the Department of Plant Reproductive Biology with 6 channel LED fixtures. The project has been realized based on our SUNsim daylight solution.

Project specifications

  • 1 chamber with a total size of 10,5 m²
  • 32 LED modules
  • Average max. intensity of 900 µmol/m²/s @ 400-800nm
  • Max. Power consumption 10 kW
  • Aging reserve of 17 percent
  • All walls had to be optimized in order to meet the thought requirements regarding the homogeneity
  • Integration in Siemens S7 control system

German Federal Environmental Office

Illumination of 3 mini ponds with 6 channel LED fixtures. The project has been realized based on our first SUNsim ecotune version including 2 UV-A channels.

Project specifications

  • 3 ponds with a total size of 9 m²
  • 135 LED modules
  • Average max. intensity of 140 W/m²/s @ 350 -750nm
  • Max. Power consumption 6.6 kW

Other Clients

Fraunhofer Institute, Leibnitz Institute, University of Potsdam, Humboldt University Berlin, University of Hohenheim, Syngenta, Subitec GmbH, DSV